Research Article

|

2020, 13(12): 3338–3346

|

https://doi.org/10.1007/s12274-020-3014-3

Enzyme-amplified SERS immunoassay with Ag-Au bimetallic SERS hot spots

Xuan-Hung Pham1, Eunil Hahm1, Tae Han Kim1, Hyung-Mo Kim1, Sang Hun Lee1, Sang Chul Lee2, Homan Kang3, Ho-Young Lee2, Dae Hong Jeong4, Hak Soo Choi3 (✉), and Bong-Hyun Jun1 (✉)

View Author's information

1 Department of Bioscience and Biotechnology, Konkuk University, Seoul 143-701, Republic of Korea
2 Department of Nuclear Medicine, Seoul National University Bundang Hospital, Seongnam 13620, Republic of Korea
3 Gordon Center for Medical Imaging, Department of Radiology, Massachusetts General Hospital and Harvard Medical School, Boston, MA 02114, USA
4 Department of Chemistry Education, Seoul National University, Seoul 151-742, Republic of Korea

Keywords: surface-enhanced Raman scattering (SERS)-based immunoassay, Au-Ag alloy, surface-enhanced Raman scattering, silica template, immunoglobulin G (IgG) detection
Full article PDF
Cite this article(Endnote)
Share this article
Metric

views: 198

Citations: 0

  • Abstract
  • References
  • Electronic Supplementary Material
Surface-enhanced Raman scattering (SERS) enables rapid detection of single molecules with high specificity. However, quantitative and sensitive SERS analysis has been a challenge due to the lack of reliable SERS-active materials. In this study, we developed a quantitative SERS-based immunoassay using enzyme-guided Ag growth on Raman labeling compound (RLC)-immobilized gold nanoparticle (Au NP)-assembled silica NPs (SiO2@Au-RLC@Ag). The enzyme amplified Ag+ reduction as well as Ag growth on the RLC-immobilized Au NP-assembled silica NPs (SiO2@Au-RLC), which resulted in a significant increase in SERS signal. In the presence of target antigens such as immunoglobulinG (IgG) or prostate-specific antigen (PSA), Ab1-Antigen-Ab2 immune complex with alkaline phosphatase triggered an enzyme- catalyzed reaction to convert 2-phospho-L-ascorbic acid (2-phospho-L-AA) to ascorbic acid (AA). As produced AA reduced Ag+ to Ag, forming an Ag hot spot on the surface of SiO2@Au-RLC, which enhanced the SERS signal of SiO2@Au-RLC@Ag in a solution with a target antigen concentration. The plasmonic immunoassay for IgG detection showed a high linearity of SERS intensity in the range of 0.6 to 9.0 ng/mL with a detection limit (LOD) of 0.09 ng/mL, while an LOD of 0.006 ng/mL was obtained for PSA. The results indicate that the sensitivity of our novel SERS-based immunoassay is higher than that of conventional enzyme-based colorimetric immunoassays.
Related Article
Cite this article

Enzyme-amplified SERS immunoassay with Ag-Au bimetallic SERS hot spots. Nano Res. 2020, 13(12): 3338–3346 https://doi.org/10.1007/s12274-020-3014-3

Download citation